Friday, June 6, 2014

Exception in thread "Thread-1" java.lang.ExceptionInInitializerError

We are using the Weblogic 12.1.1with Oracle Agile 9.3.3. After applying the hot fix, when we try to start the application we received the below error message

Please upgrade your admin data schema to 9.3.385.2
Shutting down the server...

<May 30, 2014 1:15:23 PM PDT> <Alert> <WebLogicServer> <BEA-000396> <Server shutdown has been requested by <WLS Kernel>.>
Exception in thread "Thread-1" java.lang.ExceptionInInitializerError  at weblogic.wsee.runtime.JMSStoreRoutableIDMapper.shutdown(
at weblogic.wsee.runtime.WebServicesRuntime.shutdown(
at weblogic.wsee.runtime.WseeService.haltService(
at weblogic.server.ServiceActivator.halt(
at weblogic.t3.srvr.ServerServicesManager.haltInternal(
at weblogic.t3.srvr.ServerServicesManager.halt(
at weblogic.t3.srvr.T3Srvr.shutdown(
at weblogic.t3.srvr.T3Srvr.forceShutdown(
at weblogic.t3.srvr.T3Srvr$
Caused by: java.lang.IllegalStateException: Shutdown in progress
at java.lang.ApplicationShutdownHooks.add(
at java.lang.Runtime.addShutdownHook(
at weblogic.wsee.persistence.LogicalStore.<clinit>(

From the error it is clear that the admin data schema needs to be upgrade. That means the hot fix have Database component and that needs to run after the hot fix.

I found a Database script i.e. oracle_933HF30.sql and applied to upgrade the admin data schema.

Now the application comes online without any issues.

Satishbabu Gunukula, Oracle ACE